smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: FUJITSU MHR2020AT Serial Number: NJ13T2215TUH Firmware Version: 30B8 Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 1 Local Time is: Sun Aug 15 13:21:33 2004 MEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 105) The previous self-test completed having the servo (and/or seek) element of the test failed. Total time to complete Offline data collection: ( 234) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 007 001 046 Pre-fail Always FAILING_NOW 154618843423 2 Throughput_Performance 0x0005 100 100 020 Pre-fail Offline - 145 3 Spin_Up_Time 0x0003 094 083 025 Pre-fail Always - 24321 4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 1887 5 Reallocated_Sector_Ct 0x0033 099 099 024 Pre-fail Always - 1 7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 458751 8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0 9 Power_On_Seconds 0x0032 088 088 000 Old_age Always - 1819h+16m+52s 10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 091 091 000 Old_age Always - 1467 192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 44 193 Load_Cycle_Count 0x0032 086 086 000 Old_age Always - 49810 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 32 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 1221 196 Reallocated_Event_Count 0x0032 099 099 000 Old_age Always - 1 197 Current_Pending_Sector 0x0012 001 001 000 Old_age Always - 10 198 Offline_Uncorrectable 0x0010 092 092 000 Old_age Offline - 17 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always - 393215 203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 429515210380 SMART Error Log Version: 1 ATA Error Count: 6861 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 6861 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 90 78 16 51 f0 00 08:22:32.857 READ DMA EXT Error 6860 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 98 70 16 51 f0 00 08:22:27.700 READ DMA EXT Error 6859 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 a0 68 16 51 f0 00 08:22:22.558 READ DMA EXT Error 6858 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 a8 60 16 51 f0 00 08:22:17.458 READ DMA EXT Error 6857 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 b0 58 16 51 f0 00 08:22:12.558 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: servo/seek failure 90% 1819 - # 2 Extended offline Completed: servo/seek failure 90% 1816 - Device does not support Selective Self Tests/Logging