smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: MAXTOR 4K080H4 Serial Number: 674205306226 Firmware Version: A08.1500 ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Off-line data collection status: (0x02) Offline data collection activity completed without error. Self-test execution status: ( 112) The previous self-test completed having the read element of the test failed. Total time to complete off-line data collection: ( 44) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Automatic timer ON/OFF support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 50) minutes. SMART Attributes Data Structure revision number: 11 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0 3 Spin_Up_Time 0x0027 077 077 020 Pre-fail - 2909 4 Start_Stop_Count 0x0032 100 100 008 Old_age - 29 5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 1 7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0 9 Power_On_Hours 0x0012 097 097 001 Old_age - 1992 10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0 11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0 12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 29 13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0 194 Temperature_Centigrade 0x0022 093 090 042 Old_age - 19 195 Hardware_ECC_Recovered 0x001a 100 006 000 Old_age - 7683906 196 Reallocated_Event_Count 0x0010 099 099 020 Old_age - 1 197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 1 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0 199 UDMA_CRC_Error_Count 0x001a 198 198 000 Old_age - 2 SMART Error Log Version: 1 ATA Error Count: 11 (device log contains only the most recent five errors) DCR = Device Control Register FR = Features Register SC = Sector Count Register SN = Sector Number Register CL = Cylinder Low Register CH = Cylinder High Register D/H = Device/Head Register CR = Content written to Command Register ER = Error register STA = Status register Timestamp is seconds since the previous disk power-on. Note: timestamp "wraps" after 2^32 msec = 49.710 days. Error 1 occurred at disk power-on lifetime: 1029 hours When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER:40 SC:02 SN:41 CL:2d CH:70 D/H:e8 ST:d1 Sequence of commands leading to the command that caused the error were: DCR FR SC SN CL CH D/H CR Timestamp 70 08 02 41 2d 70 e8 c4 90.713 70 08 04 3f 2d 70 e8 c4 86.648 70 08 06 3d 2d 70 e8 c4 82.584 70 08 08 3b 2d 70 e8 c4 78.342 28 08 04 8b 2c 28 e8 c5 78.341 Error 2 occurred at disk power-on lifetime: 1029 hours When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER:40 SC:04 SN:3f CL:2d CH:70 D/H:e8 ST:d1 Sequence of commands leading to the command that caused the error were: DCR FR SC SN CL CH D/H CR Timestamp 70 08 04 3f 2d 70 e8 c4 86.648 70 08 06 3d 2d 70 e8 c4 82.584 70 08 08 3b 2d 70 e8 c4 78.342 28 08 04 8b 2c 28 e8 c5 78.341 28 08 08 4b 2c 28 e8 c5 78.339 Error 3 occurred at disk power-on lifetime: 1029 hours When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER:40 SC:06 SN:3d CL:2d CH:70 D/H:e8 ST:d1 Sequence of commands leading to the command that caused the error were: DCR FR SC SN CL CH D/H CR Timestamp 70 08 06 3d 2d 70 e8 c4 82.584 70 08 08 3b 2d 70 e8 c4 78.342 28 08 04 8b 2c 28 e8 c5 78.341 28 08 08 4b 2c 28 e8 c5 78.339 28 08 08 0b 2c 28 e8 c5 78.338 Error 4 occurred at disk power-on lifetime: 1029 hours When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER:40 SC:08 SN:3b CL:2d CH:70 D/H:e8 ST:d1 Sequence of commands leading to the command that caused the error were: DCR FR SC SN CL CH D/H CR Timestamp 70 08 08 3b 2d 70 e8 c4 78.342 28 08 04 8b 2c 28 e8 c5 78.341 28 08 08 4b 2c 28 e8 c5 78.339 28 08 08 0b 2c 28 e8 c5 78.338 28 08 08 cb 2b 28 e8 c5 78.337 Error 5 occurred at disk power-on lifetime: 1029 hours When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER:40 SC:66 SN:41 CL:2d CH:70 D/H:e8 ST:d1 Sequence of commands leading to the command that caused the error were: DCR FR SC SN CL CH D/H CR Timestamp 70 08 66 41 2d 70 e8 c4 69.020 70 08 68 3f 2d 70 e8 c4 64.956 70 08 6a 3d 2d 70 e8 c4 60.891 70 08 6c 3b 2d 70 e8 c4 56.826 70 08 fe a9 2c 70 e8 c4 52.713 SMART Self-test log, version number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended off-line Completed: read failure 90% 1965 0x08702f11 # 2 Short off-line Completed 00% 1800 # 3 Short off-line Completed 00% 1778 # 4 Short off-line Completed 00% 1777