smartctl version 5.39 [i386-apple-darwin8.11.1] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.1 series Device Model: ST910021AS Serial Number: 3MH05H05 Firmware Version: 3.07 User Capacity: 100,030,242,816 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Mar 23 09:06:15 2008 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 73) The previous self-test completed having a test element that failed and the test element that failed is not known. Total time to complete Offline data collection: ( 60) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 111) minutes. SCT capabilities: (0x0001) SCT Status supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000e 100 253 006 Old_age Always - 0 3 Spin_Up_Time 0x0003 092 092 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1987 5 Reallocated_Sector_Ct 0x0033 001 001 036 Pre-fail Always FAILING_NOW 16642 7 Seek_Error_Rate 0x000f 070 060 030 Pre-fail Always - 21531636184 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 4957 10 Spin_Retry_Count 0x0013 100 096 034 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1577 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 65535 189 High_Fly_Writes 0x003a 001 001 000 Old_age Always - 1050 190 Airflow_Temperature_Cel 0x0022 056 044 045 Old_age Always In_the_past 44 (0 56 56 12) 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1155 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 943182 194 Temperature_Celsius 0x0022 044 056 000 Old_age Always - 44 (0 12 0 0) 195 Hardware_ECC_Recovered 0x001a 048 048 000 Old_age Always - 80662606 197 Current_Pending_Sector 0x0012 070 069 000 Old_age Always - 614 198 Offline_Uncorrectable 0x0010 070 069 000 Old_age Offline - 614 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 7731 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 7731 occurred at disk power-on lifetime: 4955 hours (206 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c2 b5 23 40 Error: UNC at LBA = 0x0023b5c2 = 2340290 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 c0 b5 23 40 00 02:34:35.017 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:35.010 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:32.754 READ DMA EXT 35 00 80 38 b8 d1 40 00 02:34:32.736 WRITE DMA EXT 25 00 08 b8 e4 09 40 00 02:34:32.714 READ DMA EXT Error 7730 occurred at disk power-on lifetime: 4955 hours (206 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c2 b5 23 40 Error: UNC at LBA = 0x0023b5c2 = 2340290 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 c0 b5 23 40 00 02:34:35.017 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:35.010 READ DMA EXT 35 00 80 38 b8 d1 40 00 02:34:32.754 WRITE DMA EXT 25 00 08 b8 e4 09 40 00 02:34:32.736 READ DMA EXT 25 00 10 00 3b 07 40 00 02:34:32.714 READ DMA EXT Error 7729 occurred at disk power-on lifetime: 4955 hours (206 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c2 b5 23 40 Error: UNC at LBA = 0x0023b5c2 = 2340290 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 c0 b5 23 40 00 02:34:35.017 READ DMA EXT 35 00 80 38 b8 d1 40 00 02:34:35.010 WRITE DMA EXT 25 00 08 b8 e4 09 40 00 02:34:32.754 READ DMA EXT 25 00 10 00 3b 07 40 00 02:34:32.736 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:32.714 READ DMA EXT Error 7728 occurred at disk power-on lifetime: 4955 hours (206 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c2 b5 23 40 Error: UNC at LBA = 0x0023b5c2 = 2340290 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 c0 b5 23 40 00 02:34:30.804 READ DMA EXT 25 00 08 a0 3c d2 40 00 02:34:30.804 READ DMA EXT 25 00 e8 30 eb 75 40 00 02:34:32.754 READ DMA EXT 2f 00 01 10 00 00 00 00 02:34:32.736 READ LOG EXT 61 80 80 00 00 00 00 00 02:34:32.714 WRITE FPDMA QUEUED Error 7727 occurred at disk power-on lifetime: 4955 hours (206 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c2 b5 23 40 Error: UNC at LBA = 0x0023b5c2 = 2340290 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 c0 b5 23 40 00 02:34:19.202 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:19.195 READ DMA EXT 25 00 08 c0 b5 23 40 00 02:34:19.181 READ DMA EXT 25 00 10 10 3b 07 40 00 02:34:28.554 READ DMA EXT 25 00 08 50 0a 67 40 00 02:34:26.304 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: unknown failure 90% 4957 22979632 # 2 Short offline Interrupted (host reset) 90% 4505 - # 3 Short offline Completed: read failure 90% 4499 18504955 # 4 Short offline Completed: read failure 90% 4499 18504955 # 5 Short offline Completed: read failure 90% 4499 18497155 # 6 Extended offline Completed: read failure 10% 3952 8449825 # 7 Short offline Completed: read failure 90% 3730 15926729 # 8 Extended offline Completed: read failure 10% 2545 15992712 # 9 Short offline Completed: read failure 90% 2545 15992712 #10 Short offline Completed: read failure 90% 2545 15992712 #11 Short offline Completed: read failure 90% 1339 8449825 #12 Extended offline Completed: read failure 10% 907 15715785 #13 Short offline Completed: read failure 90% 859 4042953 #14 Extended offline Completed: read failure 10% 854 4042953 #15 Extended offline Completed: read failure 10% 854 4042953 #16 Short offline Completed without error 00% 300 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 15926000 15993000 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.